RX Drugnews homepage



  • ProctoFoam-HC (Schwarz)

    DESCRIPTION

    Proctofoam®-HC (hydrocortisone acetate 1% and pramoxine hydrochloride 1%) is a topical aerosol foam for anal use containing hydrocortisone acetate 1% and pramoxine hydrochloride 1% in a hydrophilic base containing cetyl alcohol, emulsifying wax, methylparaben, polyoxyethylene-10-stearyl ether, propylene glycol, propylparaben, purified water, trolamine, and inert propellants: isobutane and propane.

    Proctofoam®-HC contains a synthetic corticosteroid used as an anti-inflammatory/antipruritic agent and a local anesthetic.

    Hydrocortisone acetate

    Molecular weight: 404.50. Solubility of hydrocortisone acetate in water: 1 mg/100 mL.

    Chemical name:   pregn-4-ene-3,20-dione, 21-(acetyloxy)-11, 17-dihydroxy-,(11(beta))-.

    Pramoxine hydrochloride

    Molecular weight: 329.86. Pramoxine hydrochloride is freely soluble in water.

    Chemical name: morpholine, 4-[3-(4-butoxyphenoxy)  propyl]-, hydrochloride.

    CLINICAL PHARMACOLOGY

    Topical corticosteroids share anti-inflammatory, antipruritic and vasoconstrictive actions.

    The mechanism of anti-inflammatory activity of the topical corticosteroids is unclear. Various laboratory methods, including vasoconstrictor assays, are used to compare and predict potencies and/or clinical efficacies of the topical corticosteroids. There is some evidence to suggest that a recognizable correlation exists between vasoconstrictor potency and therapeutic efficacy in man.

    Pramoxine hydrochloride is a surface or local anesthetic which is not chemically related to the "caine" types of local anesthetics. Its unique chemical structure is likely to minimize the danger of cross-sensitivity reactions in patients allergic to other local anesthetics.

    Pharmacokinetics:    The extent of percutaneous absorption of topical corticosteroids is determined by many factors including the vehicle, the integrity of the epidermal barrier, and the use of occlusive dressings.

    Topical corticosteroids can be absorbed through normal intact skin. Inflammation and/or other disease processes in the skin increase the percutaneous absorption of topical corticosteroids. Occlusive dressings substantially increase the percutaneous absorption of topical corticosteroids. Thus, occlusive dressings may be a valuable therapeutic adjunct for treatment of resistant dermatoses. (See DOSAGE AND ADMINISTRATION .)

    Once absorbed through the skin, topical corticosteroids are handled through pharmacokinetic pathways similar to systemically administered corticosteroids. Corticosteroids are bound to plasma proteins in varying degrees. Corticosteroids are metabolized primarily in the liver and are then excreted by the kidneys. Some of the topical corticosteroids and their metabolites are also excreted into the bile.

    INDICATIONS AND USAGE

    Proctofoam®-HC is indicated for the relief of the inflammatory and pruritic manifestations of corticosteroid-responsive dermatoses of the anal region.

    CONTRAINDICATIONS

    Topical corticosteroid products are contraindicated in those patients with a history of hypersensitivity to any of the components of the preparation.

    WARNINGS

    Do not insert any part of the aerosol container directly into the anus. Avoid contact with the eyes. Contents of the container are under pressure. Do not burn or puncture the aerosol container. Do not store at temperatures above 120°F (49°C). If there is no evidence of clinical improvement within two or three weeks after starting Proctofoam®-HC therapy, or if the patient's condition worsens, discontinue the drug. Keep this and all medicines out of the reach of children.

    PRECAUTIONS

    General:   Systemic absorption of topical corticosteroids has produced reversible hypothalamic-pituitary-adrenal (HPA) axis suppression, manifestations of Cushing's syndrome, hyperglycemia, and glucosuria in some patients.

    Conditions which augment systemic absorption include the application of the more potent steroids, use over large surface areas, prolonged use, and the addition of occlusive dressings. Therefore, patients receiving a large dose of a potent topical steroid applied to a large surface area or under an occlusive dressing should be evaluated periodically for evidence of HPA axis suppression by using the urinary free cortisol and ACTH stimulation tests. If HPA axis suppression is noted, an attempt should be made to withdraw the drug, to reduce the frequency of application, or to substitute a less potent steroid.

    Recovery of HPA axis function is generally prompt and complete upon discontinuation of the drug. Infrequently, signs and symptoms of steroid withdrawal may occur, requiring supplemental systemic corticosteroids.

    Pediatric patients may absorb proportionally larger amounts of topical corticosteroids and thus be more susceptible to systemic toxicity. (see PRECAUTIONS - Pediatric Use .)

    If irritation develops, topical corticosteroids should be discontinued and appropriate therapy instituted.

    In the presence of dermatological infections, the use of an appropriate antifungal or antibacterial agent should be instituted. If a favorable response does not occur promptly, the corticosteroid should be discontinued until the infection has been adequately controlled.

    Information for the Patient:   Patients using topical corticosteroids should receive the following information and instructions:

    1. This medication is to be used as directed by the physician. It is for anal or perianal use only. Avoid contact with eyes.
    2. Be advised not to use this medication for any disorder other than for which it has been prescribed.
    3. Report any signs of adverse reactions.

    Laboratory Tests:   The following tests may be helpful in evaluating the HPA axis suppression:

    Urinary free cortisol test

    ACTH stimulation test

    Carcinogenesis, Mutagenesis, Impairment of Fertility: Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids.

    Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results.

    Pregnancy: Teratogenic Effects. Pregnancy Category C. Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate, well-controlled studies of teratogenic effects from topically applied corticosteroids in pregnant women. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time.

    Nursing Mothers:   It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have a deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to a nursing woman.

    Pediatric Use:   Pediatric patients may demonstrate greater susceptibility to topical corticosteroid-induced HPA axis suppression and Cushing's syndrome than mature patients because of a larger skin surface area to body weight ratio.

    Hypothalamic-pituitary-adrenal (HPA) axis suppression, Cushing's syndrome, and intracranial hypertension have been reported in pediatric patients receiving topical corticosteroids. Manifestations of adrenal suppression in pediatric patients include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absense of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema.

    Administration of topical corticosteroids to pediatric patients should be limited to the least amount compatible with an effective therapeutic regimen. Chronic corticosteroid therapy may interfere with the growth and development of pediatric patients.

    Geriatric Use:   Reported clinical experience has not identified differences in responses between the elderly and younger patients. In general, dose selection for an elderly patient should be cautious using the least amount compatible with an effective therapeutic regimen and reflecting the greater frequency of decreased hepatic, renal or cardiac function, and of concomitant disease or other drug therapy.

    ADVERSE REACTIONS

    The following local adverse reactions are reported infrequently with topical corticosteroids, but may occur more frequently with the use of occlusive dressings. These reactions are listed in an approximate decreasing order of occurrence: burning, itching, irritation, dryness, folliculitis, hypertrichosis, acneiform eruptions, hypopigmentation, perioral dermatitis, allergic contact dermatitis, maceration of the skin, secondary infection, skin atrophy, striae and miliaria.

    OVERDOSAGE

    Topically applied corticosteroids can be absorbed in sufficient amounts to produce systemic effects. (See PRECAUTIONS .)

    DOSAGE AND ADMINISTRATION

    Apply to affected area 3 to 4 times daily. Use the applicator supplied for anal administration. For perianal use, transfer a small quantity to a tissue and rub in gently.

    Directions for Use.

    1. Place cap on top of container. Shake foam container vigorously for 5-10 seconds before each use. Do not remove container cap during use of the product.
    2. Hold container upright on a level surface and gently place the tip of the applicator onto the nose of the container cap. CONTAINER MUST BE HELD UPRIGHT TO OBTAIN PROPER FLOW OF MEDICATION.
    3. Pull plunger past the fill line on the applicator barrel.
    4. Hold the container and applicator at eye level. Place the index and middle fingers on the container cap flanges and the thumb beneath the container. Support the applicator with your other hand. Prime the container by pressing down firmly on flanges and then release. With initial priming, a burst of air may come out of the container. It usually requires 1-2 pumps for foam to appear.
    5. To fill applicator barrel, press down firmly on cap flanges, hold for 1-2 seconds, and release. Wait 5-10 seconds to allow foam to expand in applicator barrel. Repeat until foam reaches fill line. It usually requires 3-4 pumps for foam to reach fill line. Remove applicator from container cap. Note: If foam goes beyond fill line, it will continue to expand and flow backwards resulting in foam build-up under cap.
    6. Hold applicator firmly by barrel, making sure thumb and middle finger are positioned securely underneath and resting against barrel wings. Place index finger over the plunger. Gently insert tip into anus. Once in place, push plunger to expel foam, then withdraw applicator. CAUTION: Do not insert any part of the aerosol container directly into the anus. Apply to anus only with enclosed applicator. Do not insert any part of applicator past the anus into rectum.
    7. After each use, applicator parts should be pulled apart for thorough cleaning with warm water. Since some foam will appear under the cap, the cap and underlying tip should be pulled apart and rinsed to help prevent build-up of foam and possible blockage.

    HOW SUPPLIED

    Proctofoam®-HC is supplied in an aerosol container with a special anal applicator. When used correctly, the aerosol container will deliver a minimum of 14 applications. Store upright at controlled room temperature 20°-25°C (68°-77°F). DO NOT REFRIGERATE.

    NDC 0091-0690-10     10g

    SCHWARZ
    PHARMA
    Milwaukee, WI 53201, USA
    PC2585K    Rev. 08/04


Subscribe to the "News" RSS Feed RSS

  ۞



 

About Us   |  Privacy Policy   |  Terms of Use   |  Contact Us  

© 2012 RxDrug News 1999-2016. All rights reserved